Table R5 Physical Characteristics and Environmental Specifications for Radial-leaded Devices
RGEF
Physical Characteristics
Cont’d
Lead material
Soldering characteristics
Solder heat withstand
Insulating material
Operation temperature
RGEF250: Tin-plated copper-clad steel, 0.205mm 2 (24AWG), ?0.51mm/0.020in.
RGEF300 to RGEF1100 : Tin-plated copper, 0.52mm 2 (20AWG), ?0.81mm/0.032in.
RGEF1200 to RGEF1400 : Tin-plated copper, 0.82mm 2 (18AWG), ?1.0mm/0.04in.
Solderability per ANSI/J-STD-002 Category 3
RGEF250 and RGEF400: per IEC 68-2-20, Test Tb, Method 1a, condition a;
can withstand 5 seconds at 260°C ±5°C
RGEF500 to RGEF1400: per IEC 68-2-20, Test Tb, Method 1a, condition b;
can withstand 10 seconds at 260°C ±5°C
Cured, flame-retardant epoxy polymer; meets UL 94V-0
-40°C~85°C
Note: Devices are not designed to be placed through a reflow process.
Environmental Specifications
Test
Passive aging
Humidity aging
Thermal shock
Solvent resistance
RHEF
Physical Characteristics
Conditions
-40°C, 1000 hours
85°C, 1000 hours
85°C, 85%RH, 1000 hours
85°C, -40°C (10 times)
MIL-STD-202, Method 215F
Resistance Change
±5%
±5%
±5%
±5%
No change
Lead material
RHEF050 to RHEF200
: Tin-plated copper clad steel, 0.205mm 2 (24AWG), ?0.51mm/0.020in.
RHEF300 to RHEF1100 : Tin-plated copper, 0.52mm 2 (20AWG), ?0.81mm/0.032in.
RHEF1300 to RHEF1500 : Tin-plated copper, 0.82mm 2 (18AWG), ?1.0mm/0.04in.
Soldering characteristics
Solder heat withstand
Insulating material
Operation temperature
Solderability per ANSI/J-STD-002 Category 3
per IEC 68-2-20, Test Tb, Method 1A, Condition B; can withstand 10 seconds at 260°C ±5°C
Cured, flame-retardant epoxy polymer; meets UL 94V-0
-40°C~125°C
Note: Devices are not designed to be placed through a reflow process.
Environmental Specifications
Test
Passive aging
Humidity aging
Conditions
70°C, 1000 hours
85°C, 1000 hours
85°C, 85%RH, 1000 hours
Resistance Change
±5%
±5%
±5%
12
Thermal shock
Solvent resistance
125°C, -40°C (10 times)
MIL-STD-202, Method 215F
±5%
No change
Storage Conditions for Radial-leaded Devices
Storage conditions
40°C max., 70% RH max.; devices should remain in original sealed bags prior to use.
Devices may not meet specificed values if these storage conditions are exceeded.
Note: For the TR devices series, see the telecommunications and networking devices section.
152
RoHS Compliant, ELV Compliant
相关PDF资料
RHEF900 POLYSWITCH PTC RESET 9A HOLD
RJS 5SHORT FUSE 5A 600V GLASS SHORT RJS
RKEF050 POLYSWITCH PTC RESET 0.50A T/H
RKEF065 POLYSWITCH PTC RESET 0.65A T/H
RKEF075 POLYSWITCH PTC RESET 0.75A T/H
RKEF090 POLYSWITCH PTC RESET 0.9A T/H
RKEF110 POLYSWITCH PTC RESET 1.1A T/H
RKEF135 POLYSWITCH PTC RESET 1.35A T/H
相关代理商/技术参数
RHEH4BL 制造商:Panduit Corp 功能描述:RIBBON, HYBRID, FOR USE WITH TDP4*HE SER
RHEL81H102K1A2A03B 制造商:Murata Manufacturing Co Ltd 功能描述:CAP CER 1000PF 50V 10% RADIAL
RHEL81H102K1DBA03A 制造商:Murata Manufacturing Co Ltd 功能描述:CAP CER 1000PF 50V 10% RADIAL
RHEL81H102K1K1A03B 功能描述:多层陶瓷电容器MLCC - 含引线 1000pF 10% 50Volts RoHS:否 制造商:AVX 电容:470 pF 容差:10 % 电压额定值:3 kV 端接类型:Radial 工作温度范围: 温度系数/代码:X7R 引线间隔:5.08 mm 产品:Automotive MLCCs 引线类型:
RHEL81H102K1M1A03A 功能描述:多层陶瓷电容器MLCC - 含引线 1000pF 50volts X8L +/-10% L/S 5mm RoHS:否 制造商:AVX 电容:470 pF 容差:10 % 电压额定值:3 kV 端接类型:Radial 工作温度范围: 温度系数/代码:X7R 引线间隔:5.08 mm 产品:Automotive MLCCs 引线类型:
RHEL81H103K1A2A03B 制造商:Murata Manufacturing Co Ltd 功能描述:CAP CER 10000PF 50V 10% RADIAL
RHEL81H103K1K1A03B 功能描述:多层陶瓷电容器MLCC - 含引线 10000pF 10% 50Volts RoHS:否 制造商:AVX 电容:470 pF 容差:10 % 电压额定值:3 kV 端接类型:Radial 工作温度范围: 温度系数/代码:X7R 引线间隔:5.08 mm 产品:Automotive MLCCs 引线类型:
RHEL81H103K1M1A03A 功能描述:多层陶瓷电容器MLCC - 含引线 10000pF 50volts X8L +/-10% L/S 5mm RoHS:否 制造商:AVX 电容:470 pF 容差:10 % 电压额定值:3 kV 端接类型:Radial 工作温度范围: 温度系数/代码:X7R 引线间隔:5.08 mm 产品:Automotive MLCCs 引线类型: